Engine Coolant Bypass Valve B Control Circuit Low
Voltage on the second coolant bypass valve control line is below the expected window. Wiring faults of this kind typically come from chafing, water ingress at connector seals, or pin push-back — a wiggle test on the harness while the code is active often confirms the location.
Common causes
- high likelihood
Control wire shorted to ground
- medium likelihood
Internal short in solenoid coil
- low likelihood
Connector pins corroded - high contact resistance