B Rocker Arm Actuator Position Sensor Circuit High Bank 1
The position sensor signal for actuator B on bank 1 is above the upper diagnostic threshold. Wiring faults of this kind typically come from chafing, water ingress at connector seals, or pin push-back — a wiggle test on the harness while the code is active often confirms the location.
Common causes
- high likelihood
Open sensor element
- medium likelihood
Signal wire shorted to the 5 V reference
- low likelihood
Connector pins corroded - high contact resistance